Top products from r/ecobee
We found 62 product mentions on r/ecobee. We ranked the 73 resulting products by number of redditors who mentioned them. Here are the top 20.
1. Fyve 24 Volt Transformer, C Wire Adapter, Compatible with Nest Honeywell Ecobee Sensi Thermostats, Doorbell Transformer for All Versions of Ring Nest Hello Skybell, Extra Long 25' Cable
Sentiment score: 3
Number of reviews: 5
POWER SMART DEVICES: This C-wire kit efficiently powers your smart WiFi thermostats from popular makers such as Honeywell, Nest, Ecobee, Emerson Sensi and serves as a doorbell transformer for Ring Doorbells, Nest Hello, Skybell, etc. No more low or dead batteriesSTANDARD HOME USE: Plug in transforme...
2. 24 Volt Transformer, C Wire Adapter Thermostat, Competible with All Versions of Ring Doorbell and Thermostat for Nest Ecobee, Sensi and Honeywell, 315" Long Cable 24V Transformer
Sentiment score: 0
Number of reviews: 4
WIDELY USE: US power cable Powers your popular smart thermostats((Nest, Ecobee, Honeywell, Sensi) and doorbells(Ring Video Doorbell, Ring Video Doorbell 2 & Ring Video Doorbell Pro,Nest Skybell , etc.) and other devices that require constant 24 volt power for operation, enables you to charge your de...
3. Class II Transformer - 24 Volt AC, 40 VA, UL/CSA Approved : MGT-2440
Sentiment score: 2
Number of reviews: 4
Positive / Negative / ground Screw Terminals.LED Indicator. No user manual or documentation in the box.
4. LockState Connect LS-24VAC 24 Vac Adaptor for LS-90i
Sentiment score: 2
Number of reviews: 3
Provides 24V power when plugged into a standard 110 wall outletComplete with 20-Foot cordNon-polarity wires make for simple installation
5. ecobee3 Smarter Wi-Fi Thermostat with Remote Sensor, 2nd Generation
Sentiment score: 1
Number of reviews: 3
Works with Alexa for voice control (Alexa device sold separately).Smart, really smart - intuitively understands when to turn on your heating or cooling equipment based on your home's unique energy profile, the weather outside, and thousands of other data points to make sure you're comfortable at all...
6. Elk TRG2440 24VAC, 40 VA AC Transformer with PTC Fuse
Sentiment score: 2
Number of reviews: 3
Input Voltage: 120 VAC, 60Hz, .43A, Output Voltage: 24 Volts A.C.Auto-Resetting (PTC) Fused SecondaryGreen Power On LED, Grounding Prong & TerminalElectrical outlet mounting tabH = 4.14-Inch, W=2.74-Inch, D = 2.2-Inch.
8. Emerson 90 380 Fan Relay 24 Volt Coil, 1
Sentiment score: 3
Number of reviews: 2
Fan Relay Heavy-Duty Single Pole Nor OpenBrick-Red Color | Nonflammable | Provides A Fireproof Acoustic SealThis Is Manufactured In United StatesBrand Name: Emerson Thermostats
9. Functional Devices RIBU1C Enclosed Pilot Relay, 10 Amp Spdt with 10-30 Vac/Dc/120 Vac Coil
Sentiment score: 1
Number of reviews: 2
Relay In A Box (RIB)Coil Current: 28 mA @ 120 Vac ;HP @ 120V 1/3 NO, 1/6 NC, HP @ 240V 1/3 NO, 1/6 NCEnclosed Pre-Iwre RelayCoil Voltage Input: 10-30 Vac/dc ; 120 Vac ; 50-60 Hz ; Drop Out = 2.1 Vac / 2.8 Vdc ; Pull In = 9 Vac / 10 Vdc
10. Coleman Cable 09634 CL2 Bulk Thermostat Cable, 18-Gauge 5-Conductor 50-Feet
Sentiment score: 1
Number of reviews: 2
Works with wired thermostatsSized as 18 gauge / 5 ConductorPolypropylene insulation on copper conductorsMeets National Electric Code Article 725
11. Packard Control Transformer Class Ii Foot Mount, 40V/24V
Sentiment score: 2
Number of reviews: 2
Wire length 8". UL ListedMounting Configuration: 2 FootPrimary Voltage: 120/208/240Secondary Voltage: 24VA Rating: 40Product Depth (in.) 4.1 Product Height (in.) 2.8 Product Width (in.) 2.7Product Weight (lb.) 1.65lb
12. Lux WIN100 Automatic Heating & Cooling 5-2 Day Programmable Outlet Thermostat, Compatible with Portable A/C, Fans, and Space Heaters
Sentiment score: 0
Number of reviews: 2
PROGRAMMABLE: This 5-2 day thermostat allows you to program weekdays and weekends at different temperaturesEASY TO USE: Comes with easy to use touch keys and displays the current temperature for easy referenceINSTALLATION: No installation or wiring, easy to plug in and select the desired heatCOMPATI...
13. ecobee Smart Thermostat 4 Heat-2 Cool with Full Color Touch Screen
Sentiment score: 2
Number of reviews: 2
Intuitive User Interface makes it easy to quickly set a personalized programBuilt-In Wi-Fi enabled. Adjust settings anywhere, anytime via Computer, Smartphone, or TabletBuild-In Live Weather Functions to assist in saving the most energy possibleIntuitive User Interface makes it easy to quickly set a...
14. INNOVA 3320 Auto-Ranging Digital Multimeter
Sentiment score: 1
Number of reviews: 1
UL certified product designed to safely and accurately troubleshoot a variety of automotive and household electrical problemsAuto-ranging scales eliminate the need to dial in the correct range when making electronic measurementsFeatures large digital display and color coded LED's for battery quick c...
15. Honeywell AT140A1000 40Va, 120V Transformer - 60 Hz.
Sentiment score: 0
Number of reviews: 1
This is a genuine OEM replacement part.Brand name: HoneywellModel number: AT140A1000Country of Origin: China
16. Aprilaire 600M Whole Home Humidifier, Manual High Output Furnace Humidifier, Large Capacity Whole House Humidifier for Homes up to 4,000 Sq. Ft.
Sentiment score: 1
Number of reviews: 1
BUY WITH CONFIDENCE This humidifier was designed and manufactured in the U.S.A. by Aprilaire – the inventor of the whole home evaporative humidifier, and the leader in indoor air quality solutionsFULL COVERAGE up to 4,000 square feet in tightly built homes with a capacity of 17 gallons per dayMANU...
17. MG ELECTRONICS MGT2420 TRANSFORMER,24VAC 20VA UL APPROVED
Sentiment score: 2
Number of reviews: 1
DOOR ACCESS CONTROLS AND SECURITY CAMERASMGT2420POWER TRANSFORMERSPOWER: 20 VAVOLTAGE: 24 V
18. Command Refill Strips, Medium, White, 9-Strips
Sentiment score: 0
Number of reviews: 1
INCLUDES - 9 Indoor Small Replacement StripsRE-HANG HOOKS – Reorganize when inspiration strikes! Command Small Refill Strips make it easy to hang and rehang your Command indoor hooks, damage-free.ORGANIZE DAMAGE-FREE - Say goodbye to holes, marks, or sticky residue on your walls, doors, cabinets, ...
19. 24 Volt Transformer, C Wire Adapter Thermostats, Compatible with Ecobee, Nest and Honeywell Smart Wifi Thermostat, Ring Nest Hello Skybell August Doorbell (White)
Sentiment score: 0
Number of reviews: 1
24V C WIRE POWER ADAPTER: plugs into your standard 110 v/120 v outlet and converts to 24 volt AC current24 VOLT TRANSFORMER FOR THERMOSTAT AND DOORBELL: powers up smart thermostats for (Nest, Ecobee, Honeywell, Emerson Sensi, Hive, etc.) and doorbells (Ring, Nest Hello, Skybell, August) that require...
20. Brushless Direct Drive Blower, ECM, 1/2 HP
Sentiment score: 0
Number of reviews: 1
<b>Price For:</b> Each <b>Motor Shaft Design</b>: Flat <b>Motor Service Factor</b>: 1.00 <b>Frame</b>: 48 <b>Motor Bearings</b>: Ball <b>Motor Enclosure Design</b>: Open Air-Over <b>Phase</b>: 1 <b>Ins. Class</b>: B <b>Motor Mounting Type</b>: Band <b>Capacitor Required</b>: No <b>Motor Sub Applicat...
Ok. Actually, it is good that we confirmed HRV activation will turn on the furnace fan.
Disconnect the ACC+ to G bridge at Ecobee.
Based on the tests, we know now that when the thermostat activates fan, the signal of the G wire is not sensed by the HRV and is just passed through to the furnace.
So the only way to use Ecobee to control the HRV is using a dry contact switch between HRV terminals 2 and 6 with terminals 2 and 3 bridged.
The Ecobee ACC+/- connection is a dry contact switch. But that means you will need 2 free wires running from the ecobee to the HRV.
It is possible to use only 1 free wire (which you could free easily using the PEK), by adding a 24vac SPNO relay at the furnace end. This is the cheaper/easier solution if you can’t run new wire easily.
You can buy either a SPNO or SPNO/NC relay. Like this on Emerson 90-380 Relay, Fan, 24 VAC https://www.amazon.com/dp/B000LDCPQS/ref=cm_sw_r_cp_tai_w.qOAb081R1GE
On the relay, connect ecobee ACC+ to coil 1 and coil 2 to furnace Common. Then connect relay NO to HRV #2 and relay COM to HRV #6. Bridge HRV #2 and 3.
ok I'll look around if I can can find one locally.
If not I'll probably just order the one on Amazon.ca it's $19.04 CAD shipped. https://www.amazon.ca/Emerson-90-380-Relay-Fan-VAC/dp/B000LDCPQS
Found a manual for it here. Not clue how to read it, however I'm sure you will ;)
https://www.mouser.com/ds/2/459/Cat_06_pg0115-1627.pdf
I'll let you know once I get one! Thanks again for all the awesome help (and patience!)
No doubt your remark was meant in jest, but to set the story straight, the ecobee3 got its name because it was the third hardware model of thermostat released by ecobee (the ecobee Smart Si and EMS Si were more or less identical, with one targeting home owners and the other targeting commercial establishments). Here's a complete list of their thermostats:
If you have ecobee4 you can simply ask Alexa:
"Alexa, ask ecobee to turn fan on" (Remember to have her turn the fan off too! )
"Alexa, ask ecobee to turn fan off"
&#x200B;
If Alexa doesn't follow those commands make sure your ecobee is named "ecobee". You can check and change this in the Alexa app on your phone.
&#x200B;
https://www.amazon.com/ecobee-Inc-plus/dp/B071672K2R
There is a list of commands at that link. You must have the ecobee plus skill enabled on alexa to do this. If you don't simply ask Alexa:
"Alexa, enable ecobee plus skill"
Alternatively, you can turn on the fan from the thermostat itself. It's nested under settings and "test equipment" This is why I suggested to just ask Alexa.
I have a heat only system as well. My old thermostat only used two wires. I called ecobee and we were trying to get 24v power to the ecobee. I ended up buying a transformer from Amazon and used the power from there.
External Transformer plug into power supply wires coming from this adapter connect to RC and C terminal and thermostat wire R wire to RH terminal and W wire w1 terminal.
This is the transformer I went with bc it woukd be easier for me.
MG ELECTRONICS MGT2420 TRANSFORMER,24VAC 20VA UL APPROVED https://www.amazon.com/dp/B0010GR07O/ref=cm_sw_r_cp_apa_6YxeAbX9XCVRH
Ya, neither did mine, which is why I ran a full new 5-wire thermostat wire. I was able to just tie the new wire to the thermostat side of the old wire and then pull it down and through. I did have a couple staples to remove, but it worked out pretty well!
Hi...follow-up question on the same subject. previously I successfully setup an ecobee Tstat on a boiler that has T/T connections using a transformer and the relay. It is working fine with no problems. I would like to replace 2 other basic Tstats with Ecobees on the same boiler (3 zone boiler). I completely understand that they would each need their own relay, and that you are suggesting that 2 can run off the same transformer. Do you think the same transformer can run 3 ecobees? What, if any are factors that would affect this? This is the transformer I am using: https://www.amazon.com/gp/product/B01HPJT7C0/ref=oh_aui_detailpage_o03_s01?ie=UTF8&psc=1
&#x200B;
Thanks in advance!
Is there any way you can just power it with a separate transformer like this one?
https://www.amazon.com/dp/B0007N5LJK
That’s what I’m doing with two of my four ecobees and they’ve been great.
So the Ecobee most likely runs off of DC power. This will be supplied by a rectifier and a voltage regulator from the R terminal (24v AC from your HVAC equipment). 24v AC rectifies to about 35v DC. The ecobee will step this down to maybe 12 or 5v DC for use internally. So putting 24v DC on the R terminal should still work as expected, however it's not recommended as it's not a supported configuration. However, it shouldn't cause damage.
To answer your questions, get a 24v AC transformer and relay that accepts a 24v AC signal and capable of switching 1v DC. Your circuit diagram looks correct.
Looks like digikey does not have a wall transformer in stock. In short: the Ecobee needs ~4VA to run. Look for a transformer that can deliver at least 10va (or 10 watts) LockState Connect LS-24VAC 24 Vac Adaptor for LS-90i
https://www.amazon.com/dp/B0071IWJ7G/ref=cm_sw_r_cp_api_hzAtybVP4AJ5X
http://www.digikey.com/product-detail/en/phoenix-contact/2903337/277-10089-ND/4755341
Double check me that these meet requirements.
It looks like your best bet to power the Ecobee is to buy one of these or similar. It won't be the best cosmetic solution, but it will function well.
I think your problem is the C wire... per your comment you have RC/W/Y/G... you need a C.
If your unit has a C terminal but unused, you can use the adapter ecobee's include to make a 4 wire system work. If not, then you might need something like this:
https://www.amazon.com/Transformer-Honeywell-Thermostat-Fyve-Global/dp/B075PN6NCV/ref=sr_1_3?ie=UTF8&amp;qid=1511237224&amp;sr=8-3&amp;keywords=c++wire+adapter
in addition to the adapter ecobee includes to give you power. Then treat that as your C... I haven't personally done this, maybe someone here can give you more feedback.
Hi All, thanks for the help. I ordered https://www.amazon.com/gp/product/B0071IWJ7G/ref=oh_aui_detailpage_o00_s00?ie=UTF8&amp;psc=1 and it works! This thing should be promoted and shame on ecobee if they don't because they have a sponsorship with fast-stat (which will not work for this system).
I’m using one of these, works great!
https://www.amazon.com/Transformer-Thermostat-Competible-Versions-Honeywell/dp/B07DJ7RHS5/ref=sr_1_2_sspa?ie=UTF8&amp;qid=1542899554&amp;sr=8-2-spons&amp;keywords=viivria+24+volt+transformer&amp;psc=1
Thank you for the response, @dapala1
&#x200B;
Yes, the two black wires are from the 24V transformer C wire adapter: https://www.amazon.com/Adapter-Transformer-Honeywell-Thermostat-Fyve/dp/B075PN6NCV
&#x200B;
If I tape up the other black wire, the ecobee will not turn on. Should I try something different?
Looks like you have everything you need..should be able to use pek
Or you get one of these
24 Volt Transformer, C-Wire Power Adapter for Nest Honeywell Emerson Sensi, Nest Hello Skybell Smart WiFi Thermostat and Doorbell Power, 25 ft Cable by Fyve Global https://www.amazon.com/dp/B075PN6NCV/ref=cm_sw_r_cp_apa_i_mshRDb7B8FXEX
Do you have a multimeter?
Set it AC and check the R wire w/ the hot (red) lead and the C should be your negative/common (black) and the multimeter should show about 24V.
this is like an outlet where you have a positive and a neutral wire, these 2 wire are what the ecobee needs at minimum to turn on.
If you don't mind an external transformer near the thermostat, you can just buy this:
https://www.amazon.com/Transformer-Honeywell-Thermostat-Fyve-Global/dp/B075PN6NCV
The wires from the transformer go into Rc and C. Your current wires go into Rh and W. I did this for my parents. Works amazing.
Thank you so much. I was on and off the phone with ecobee earlier and they couldn't give me a straight answer.
I had already purchased this relay and have it ready to install.
https://www.amazon.com/gp/aw/d/B000LESCI2?psc=1&amp;ref=yo_pop_mb_pd_title
I will give it a shot later this evening. Thanks again.
Not necessarily. I have 3 sensors through my house, but the common factor is the system itself. In the summer, the upstairs is too hot, in the winter the upstairs is still too cold.
The sensors do help balance it out, but the limitation is that the system is routed poorly and the upstairs has bad circulation.
In this case, my husband and I get a window AC during the summer, and a space heater during the winter.
If your landlord is concerned about fire, get a ceramic heater that does not actually have any live wires. Something like this: https://smile.amazon.com/Lasko-5790-Oscillating-Ceramic-Control/dp/B008UO7I1W/
I also connect it to a thermostat like this: https://smile.amazon.com/Lux-Heating-Cooling-Programmable-Thermostat/dp/B000E7NYY8
My husband is notorious for leaving a room without remembering to turn off the space heater, so it's nice to have both a temperature sensor that prevents it from getting too hot or too cold and also timer so that it's not running when I know we aren't going to be in our bedroom anyway.
You can use the thermostat to set your schedule, just as you would with the ecobee or another "smart" thermostat. Plug your AC or heater into it, make sure to turn the device up to HIGH so it doesn't inadvertently shut off with the integrated thermostat before the plug turns it off. And you will have your own climate control :)
Link to the skill.
Would be useful to put that in the post, /u/Mikey-A-.
I literally just had this issue, and fixed it two days ago.
So what kind of wire do you have at your existing thermostat? You're using two, but are there other wires present? If not, you're going to have to run a new thermostat wire like I did. Here's 50 ft of it from amazon.com
https://smile.amazon.com/gp/product/B0026H8L7E/ref=oh_aui_detailpage_o03_s00?ie=UTF8&amp;psc=1
Once you have that run, you need to wire it up. You need to use three wires for a heat only application (I don't have central air, and it's controlling one zone on a oil fired boiler). The white, the red, and blue. I just cut the others, and wrapped them around for later use. Do you want the ecobee to control all zones at once? Or just one zone? I'm assuming you want it controlling only one zone.
The White and Blue (this will be your common) wires go to the yellow wires on either your zone valve (in my case) or a pump. Not sure of your configuration. I had one pump, and several zone valves. Others have several pumps. All depends on what you have.
Okay, so the red will be wired to your 24VAC supply from your transformer. I used wire nuts, and made it in parallel to the other devices. This is important. Use a multimeter to determine what your voltage is ( put it on ~V setting). If you have 120V going to your thermostat, you'll probably fry it.
Here's how I wired mine:
White- Yellow on your Zone Valve. This connection is only two wires. Your white, and one yellow.
Blue- Common. Other yellow on the same zone valve. It's AC so it doesn't matter which one you wire to which yellow, but your common is called common for a reason... every zone valve you have needs to be wired in parallel to each other with the blue, AS WELL AS the white from your 24vac transformer. I have three zones, so five wires total (one yellow from each valve, plus white from 24vac, plus blue from thermostat) are wire nutted together.
Red- 24VAC on transformer (the wire coming out of my transformer was black in color, but it should be red). This is the hot one.
That should do it. Let me know if you have any questions. This took me several hours of troubleshooting, and the internet was surprisingly not a lot of help. I'm sorry in advance if my technical writing skills aren't the best.
I didn't have a c wire at my thermostat, so I bought an adapter on Amazon for around $16. It simply plugs into a nearby outlet.
The one I used is https://www.amazon.com/Adapter-Transformer-Honeywell-Thermostat-Fyve/dp/B075PN6NCV
It comes with installation instructions which are available on the Amazon page. There's also YouTube videos.
Thanks for taking the time to explain.
Yes, the Transformer is a wall plug with 24V DC output: https://www.digikey.com/product-detail/en/triad-magnetics/WSU240-0500/237-1459-ND/3094985
The Ecobee is turning on with 24VDC though which confuses me.
So, I'm thinking about ordering this fella which should do the trick, right: https://www.amazon.com/LockState-Connect-LS-24VAC-Adaptor-LS-90i/dp/B0071IWJ7G/
Edit: I would also need a AC relay then I guess, right? Guess I was just assuming DC in the entire circuit. Never did any AC electronics so far...
Edit 2: Just found this quote: "the incoming voltage to the ecobee interface unit is 24V AC (alternating current) but the power going to the thermostat is 12V DC" here https://www.stevejenkins.com/blog/2010/11/product-review-ecobee-smart-thermostat/
Ecobee has been around since 2007. Their previous products include the original ecobee and the Smart SI. I guess you could call those the Ecobee 1 and 2.
As for any smart device dependent on the cloud, if ecobee were to suddenly go out of business and shutter their server, any kind of remote management functions would cease. No weather data on the thermostat, either. You'd still be able to program it from the thermostat itself only, since the ecobee has no embedded web server for the end user to access.
Yes this is what I did. You're going to need to run additional wires to your thermostat. There's no way around that. What I used is this 24V transformer and this 2 conductor thermostat wire. One end goes to the two power terminals on transformer (nothing gets connected to ground) and the other end goes to RC and C on the Ecobee. It doesn't matter which one is which since it's A/C voltage. Your already existing heating wires go to RH and W1.
step down transformer
Instructions from an Amazon reviewer:
Same predicament! It is on amazon.ca. https://www.amazon.ca/ecobee3-Thermostat-Sensor-Wi-Fi-Generation/dp/B00ZIRV39M/
I actually ended up getting it to work with this.
It's 185$ new on amazon... is this the right one:
https://www.amazon.com/gp/product/B00ZIRV39M
If you are looking for a not so smart but reliable thermostat switch, I recently got one of these and have been reliable: Lux WIN100 Automatic Heating & Cooling 5-2 Day Programmable Outlet Thermostat, Compatible with Portable A/C, Fans, and Space Heaters https://www.amazon.com/dp/B000E7NYY8/ref=cm_sw_r_cp_api_i_bAIXDbYAV1WBB
This is the transformer I put in:
https://www.amazon.com/gp/product/B000K2EC7K/ref=oh_aui_detailpage_o00_s00?ie=UTF8&amp;psc=1
Delivers 24vac.
I was looking at transformers. This one particularly: 24 Volt Transformer, C Wire Adapter Thermostats, Compatible with Ecobee
Until I came across a customer review with this picture and caption: This destroyed my Honeywell Lyric Thermostat
Would you be willing to share pictures of your ecobee setup with your transformers?
@kulidan were you able to find any more information?
&#x200B;
I bought a PDRYCB300 and an ecobee4. Unfortunately I have not been able to get the thermostat to talk to my slim duct system. (LMDN186HV) I bought a separate transformer which was able to power the ecobee4 but despite what I believe are the right wire mappings it does not send any commands to the unit. Note I attached this transformer directly to the ecobee4 on the RC and C terminals. I may try routing this through the dry contact next, but the exact configuration is not clear to me.
https://smile.amazon.com/gp/product/B07DJ7RHS5