GAS TYPE & PRESSURE - Gas Type: Natural Gas (NG). Inlet gas pressure: 1/2 PSI. Outlet pressure range: 3" - 6" Water ColumnPIPE THREAD SIZE - 3/4" Inlet & 3/4" Outlet FPT GAS PIPE. Make sure you measure the gas pipe or regulator opening as close to 1 inch as shown in the picture’s table.CAUTION - This regulator has 1" openings for 3/4" gas pipes. The 3/4" gas pipe means interior diameter 3/4" but outside diameter is 1", refer to the pictures before buying.MARKING - Model: RV48L, Marking: 1/2 PSIG, Po 3" - 6". Inlet pressure 1/2 PSI. Adjustable outlet pressure 3"-6" Water Column.OPERATE TEMPERATURE - 32°F - 225°F (0°C - 107°C). Do not install the regulator too close to the heating equipment or use in very cold environment. Heat or cold can change the resistance of the spring inside the regulator.
Check price on Amazon

2 Reddit comments about Maxitrol RV48L Natural Gas Pressure Regulator, 1" In and Out Opening, 3/4" FPT Thread,1/2 PSIG Inlet Pressure, 3"-6" WC Outlet Pressure:

u/HeadOfMax · 4 pointsr/KitchenConfidential

Take the grates off and the burners out. On the back side of where the valves are are the orifices. Clean the hole in the middle out with a toothpick. If this doesn't work you need to turn a bunch of them on and then watch them while you turn another on. If the flames get lower you have a gas supply problem. The problem is most likely in the regulator. Follow the gas line from the wall to the range and before it goes into the range should be the regulator. They keep the gas pretture between 3-5 inches of water column. There should be a cap on the center you can take off and under a scree to adjust the pressure. If you back the adjuster screw put too much it will fall out. I would get a new regulator the regulator itself should cost around $25 and will require a few pipe wrenches to replace. This one should work.

https://www.amazon.com/Maxitrol-Pressure-Regulator-Natural-52-1011/dp/B00851MUGS

You also might have an issue with the quick disconnect on the supply line. Take it off and make sure it isn't caked with grease and moves freely. You can use degreaser to clean it just make sire to lube it with wd-40 after.


The caps OK those burners do sometimes get warped and when they do they lose some gas around the seam. Make sure they aren't losing any gas from the seam.

u/Scizmz · 2 pointsr/DIY

Yeah you basically need an in line regulator.
Along the lines of this. https://www.amazon.com/dp/B00851MUGS/ref=cm_sw_r_cp_apa_5aBfAbG9Y0VDV