Reddit reviews Furnace Hot Surface Ignitor Direct Replacement for Carrier Bryant Payne OEM Part LH33ZS004
We found 2 Reddit comments about Furnace Hot Surface Ignitor Direct Replacement for Carrier Bryant Payne OEM Part LH33ZS004. Here are the top ones, ranked by their Reddit score.
Model Number: CECOMINOD002711Item Package Length: 6.099999993778"Item Package Width: 3.099999996838"Item Package Height: 3.099999996838"
https://www.amazon.ca/Furnace-Surface-Replacement-Carrier-LH33ZS004/dp/B00E3CDPLM/ref=mp_s_a_1_3?ie=UTF8&qid=1539210563&sr=8-3&pi=AC_SX236_SY340_QL65&keywords=hot+surface+ignitor&dpPl=1&dpID=511UGaXJAIL&ref=plSrch
You need this
Same thing mine did. Looks like you may have the same igniter. Bryant/carrier etc. It's a pretty universal igniter.
http://www.amazon.com/gp/product/B00E3CDPLM/ref=oh_aui_detailpage_o00_s00?ie=UTF8&psc=1
If its not the same, you should be able to Google the right one using your unit's model#.
If it's the same one, only one screw holds it to the bottom of the burner assembly.
Obviously, I should tell you that only qualified individuals should work on a gas furnace. BUT, if you decide to look into replacing the igniter yourself, it's not too hard. Unplug electrical power. Shut off the gas at the hard line. I like to wait a few minutes after that. The igniter has a molex-type connector that should wiggle off. One small screw holds the igniter's plate in, and the igniter tips and slides out.
You might want to do this before ordering a replacement. Inspect the element for imperfections and burned spots. If any exist, it's probably bad.
To reinstall, do the same in reverse. I like to take a few pics in case I had to move or remove anything else to get to it.